Advanced Reverse Osmosis Water Filtration System
Installation and Operating Instructions
Models RO-3000 and RO-3500 (with electronic TDS monitor)
RO-3000/RO-3500 Operating Specifications YOUR WATER
Pressure Range 40-100 psi (2.8-6.89 bar)
Temperature Range 40-100˚F (4.4-37.8˚C)
Total Dissolved Solids less than 1500 ppm
Maximum Hardness*† 10 gpg (171 mg/l)
Sulfide, Iron and Manganese† less than 0.01 ppm
Chlorine In Water Supply less than 2 ppm
Water Supply pH Limits 4-11
Turbidity 1 NTU Max.
MODEL #:
DATE OF PURCHASE:
* IMPORTANT! If the hardness of your water is above 10 gpg (171mg/L), lime
scale will build up rapidly on the membrane. Scale buildup will plug the
membrane and make the system ineffective. We do not recommend these
reverse osmosis systems be used with water in excess of 10 gpg (171 mg/L)
hardness, unless the water is softened prior to the reverse osmosis system.
† See your local dealer or water treatment specialist to reduce these
substances in your water.
NOTE: If your water pressure and temperature are at the low end of the listed
range (40 psi [2.8 bar] and 40°F [4.4°C]), and the TDS level is near the maximum
(1500 ppm), the system will not function properly. Under these extreme
conditions, pre-warming the supply water using a 25-ft. (7.62 m) coil of tubing
between the saddle valve and the system, and/or installing a booster pump to
increase the water pressure will allow the system to perform effectively.
WARNING: Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
NOTE: Substances reduced are not necessarily in your water. System must be
maintained according to manufacturer's instructions, including replacement of
filter cartridges.
Operating Specifications
IMPORTANT! Before installing this reverse osmosis system, make certain your
water supply complies with the following operating specifications. Failure to do
so may reduce the effectiveness of the system and will void the warranty.
Consult your local water treatment utility or a certified water testing lab to
determine the quality of your water and use the table below to record your
results for future reference.
System Dimensions
System Dimensions 13.75"w x 4.75"d x 12.75"h (349 mm x 121 mm x 318 mm)
System Weight 6.1 lbs. (2.7 kg)
Tank Dimensions 11.3"d x 16.75"h (287 mm x 425 mm) (with valve)
Tank Capacity 1.9–3.2 gal. (7.2–12.1L) (Depending on water pressure)
Tank Weight (full) 40 lbs. (18.2 kg.) (Depending on water pressure)
Production Capabilities
* Tested by NSF International according to NSF/ANSIStandard 58 has given 7.6
gallons per day. Source water test parameters are 50 psig, 77ºF, pH of 7.5 ± 0.5
and 750ppm total dissolved solids.
The RO-3000 is Tested and Certified by NSF International against
NSF/ANSI Standard 58 for the reduction of Total Dissolved Solids,
Fluoride, Turbidity, Lead, Selenium, Copper and Cysts.
The RO-3500 is Tested and Certified by NSF International against
NSF/ANSI Standard 58 for the reduction of Total Dissolved Solids,
Fluoride, Turbidity, Nitrate/Nitrite, Lead, Selenium, Pentavalent
Arsenic, Copper, Cadmium, Hexavalent Chromium, Trivalent
Chromium, Barium, Cysts and Radium 226/228.
Hand or Electric Drill
(Cordless Recommended)
Phillips Screwdrivers
(2) Adjustable Wrenches
Drill bits: 1/8, 1/4, & 3/8-inch
File
Safety Glasses
Utility knife or tube cutter
Needle-nose pliers
Measuring tape
If sink does not have hole for
separate faucet:
Center Punch
•1
1
4-Inch Bi-metal or
Carbide-Tipped Hole Saw
Respirator
Tools and Materials Required
KEEP THIS MANUAL
NOTE: Not all tools may be necessary for
installation. Read installation procedures
before starting to determine if additional
tools are necessary.
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - KEEP THIS MANUAL

Advanced Reverse Osmosis Water Filtration SystemInstallation and Operating InstructionsModels RO-3000 and RO-3500 (with electronic TDS monitor)RO-3000

Pagina 2 - How Reverse Osmosis Works

Page 10MaintenanceUse only the replacement elements and parts referred to in thismanual. Failing to do so will void your warranty.Replacing the Pre-Fi

Pagina 3 - Replacement Parts

Page 11Questions? Call our Toll Free Technical Support Departmentat 800-861-8758Monday through Friday, 7:30 a.m. to 5:00 p.m. Central Standard Time.Ma

Pagina 4 - Installation

Troubleshooting GuideIf you are experiencing a problem not listed in this manual, shut off the watersupply at the saddle valve, and close the tank val

Pagina 5 - 5. Installing the Drain Clamp

Page 13Performance DataImportant Notice: Read this performance data and compare the capabilities of this system with your actual water treatment needs

Pagina 6

Page 14Performance DataArsenic Fact SheetArsenic (abbreviated As) is found naturally in some well water. Arsenic in waterhas no color, taste or odor.

Pagina 7 - Troubleshooting

Page 15PENTEK ONE YEAR LIMITED WARRANTYPentek warrants to the original owner (under normal use): Reverse Osmosis Systems to be free from defects in ma

Pagina 8 - MATERIALS REQUIRED:

502 Indiana Ave • Sheboygan, WI 53081Toll Free Technical Support: 800-861-8758 • Technical Support: [email protected]

Pagina 9

Page 2General PrecautionsWARNING: The RO-3000 and RO-3500 systems contain a replaceablemembrane critical to the efficiency of the system. Replacement

Pagina 10

Page 3A ROR Replacement Cartridge Kit 155923B ROM-230T Membrane (RO-3000) 155854C ROM-230TN Membrane (RO-3500) 155855D Nitrate/Nitrite Test Kit (RO-35

Pagina 11 - Maintenance continued

Page 41. Installing the Saddle ValveWARNING: Use of a hand drill is recommended. To protect yourself from serious injury orfatal shock when using an e

Pagina 12

AECBDFPage 5A6"5BDC1⁄4”11⁄4”A1⁄4"11⁄4"3Installation Continued2. Selecting the Faucet LocationThe drinking water faucet should be positi

Pagina 13

Page 6B9AC5/8"Installation Continued6. Connecting the Faucet to the DrainNOTE: THIS IS A GRAVITY DRAIN LINE. ANY LOOPS, KINKS OR SHARP BENDS MUST

Pagina 14 - Arsenic Fact Sheet

Page 711AB1012ABrine SealInstallation Continued10. Connecting the Saddle Valve (A) Locate pre-installed white plastic tubing found on the left hand si

Pagina 15 - IOWA RESIDENTS ONLY:

Page 8Installation Continued14. System Startup (Continued)(F) Completely open the saddle valve until it comes to a stop. Allow water to drip from the

Pagina 16 - 146250 12/03

Page 9Testing your Pentek Reverse Osmosis SystemModel RO-3000Reverse Osmosis System1. Total Dissolved Solids (TDS) TestNOTE: Under NSF/ANSIStandard 58

Comentarios a estos manuales

Sin comentarios